Further documentation about replacement parts, products-total summaries, comparison tables, characteristic information, manuals, see the Info Center
PDF-brochure
The humimeter GF2 building moisture meter in this configuration makes the tasks and everyday work of a building surveyors quite easy. Determine the water content in floor screed without a costly CM measurement or determine the moisture in insulating materials and brickwork. Estimate the drying cycle or the drying process. Check if your plaster, wood or parquet have already reached the right water content. Furthermore you are able to measure the air humidity or the surface temperature with an infrared sensor. If the air quality is necessary for your work you can determine the CO2 content easily with the pluggable CO2 sensor.
Picture |
Sensor typ |
Application |
round measuring plate, fix mounted
article no. 13140 |
Building moisture meter with diverse calibration curves for building materials. Choose the correct calibration curve using the arrow keys and press the device onto the material. It is obligatory that the measuring instrument rests on an even and cleaned measuring area. | |
attached conductance electronics for GF2 pluggable electronics box with 1 meter cable for connecting external conductivity sensors with BNC connector
article no. 13141 |
Necessary adapter for the connection of all sensor types based on the measuring method of conductance with the humimeter GF2.
|
|
GF2 hand electrode
article no. 12847 |
Measuring plaster to evaluate the approval for subsequent works (tiling, paperhanging, paintwork) in new buildings resp. after water damages.
Checking adequate drying of wood, parquet and so on in order to prevent the formation of shrinkage tears in wooden floors because of a further drying of the wood. |
|
GF2 ram electrode
article no. 12630 |
Checking adequate drying of wood, parquet and so on in order to prevent the formation of shrinkage tears in wooden floors because of a further drying of the wood with the building moisture meter humimeter GF2. | |
GF2 pair of plug-in electrodes
article no. 13011 |
Measuring plaster to evaluate the approval for subsequent works (tiling, paperhanging, paintwork) in new buildings resp. after water damages with the building moisture meter humimeter GF2. | |
GF2 pair of flat electrodes
article no. 13012 |
Condensation and water damages in insulation material, residual moisture measurement in impact sound insulation below the floor screed after water damages.
Essential depth measurement of ascending moisture, especially for exsiccation processes after water damages deep in the brickworks. Checking the drying of fill in deep layers, especially in case of an unequal fill and consequentially resulting floor unevenness. |
|
pluggable rel. humidity sensor air humidity 0..100% temperature: -10..+60°C |
article no. 12514Connection of an external air humidity and temperature sensor. Via measuring the rel. humidity the appearance of mould can be prevented. At climatic conditions of more than 65% r.h. there may arise mould spores on damp areas. The measuring data can automatically be saved in adjustable intervals.pluggable r.h. sensor
with 2m connecting cable:
air humidity 0..100%
temperature: -10..+60°C
article no. 12032In addition to the points above, this sensor offers a 2m connection cable. This enables a measurement also in far-off areas. Additionally, the sensor can be mounted stationary and only be connected to the device if required.pluggable r.h. sensor 0.5m stainless sensor tube,robust design:
air humidity 0..100%
temperature: -10..+60°C
article no. 13159In addition to both above described applications, with this sensor also the relative humidity and the temperature in the brickwork can be measured. The sensor is equipped with a stainless sensor tube that can problem-free be used also in brickwork, concrete and floor screed.pluggable CO2 sensor:
CO2 range 0..5000ppm
(+/- 50ppm +3%)
article no. 12964Connection of an external CO2 sensor.
This sensor shows the concentration of CO2 up to a maximum of 5000ppm (parts per million). At measuring values below than 800 ppm the ambient air quality is considered as good, values between 800 and 1400 ppm reveal a medium to moderate ambient air quality.pluggable IR temperature sensor:
temperature: -25..125°C
1:10 optics
article no. 12513Connection of an external infrared temperature sensor. This sensor is equipped with 1:10 optics. This equates a measuring area of 16cm diameter at a distance of 1 meter. With this sensor you can easily detect areas of weak insulation in the wall. Also the functioning of the underfloor heating can be controlled.
Art. No. | Picture | Extended Accessories |
---|---|---|
12278 | humimeter USB data interface module with LogMemorizer measuring data recording and analysing software on USB flash drive incl. USB cable for PC | |
11929 | Plastic case for humimeter GF2 | |
12146 | Set of 20 replacement tips for measuring electrodes, without isulation 40mm long | |
11775 | Set of 20 replacement tips for measuring electrodes, without isulation 60mm long | |
11482 | Set of 2 replacement tips for measuring electrodes, isulated, 60mm long | |
13160 | Set of measuring bushes for floor screed: Plastic bush for driving in a bore hole of a diam eter of 12mm. 20 bushes incl. plug and one hammering aid Suitable for humidity and temperature sensor (Art. No. 13159) |
|
13066 | Integrated sensor for parquet floor GF Measurement of relative humidity and temperature | |
12857 | Cabel for integrated sensor for parquet floor GF for connection of the integrated sensor for parquet floor GF (art. no. 13066) to a humimeter device, cable length 2 meters | |
12881 | BNC connecting cable ∅4mm, 100cm Länge (spare part) | |
13224 | Extension cable of 8 meters length for humimeter RH2 and GF sensors | |
13051 | Wall holder / anti-theft protection for GF2 |